| Author |
Message |
johndixon
Joined: 26 May 2003 Posts: 1
|
Posted: Mon May 26, 2003 5:58 pm Post subject: POTTERTON COMBI ch boiler - heating ok, hot on and off |
|
|
| i have a potterton puma combi boiler and am having problems with the hot water supply. the central heating is working fine but when i use the hot water it comes on for a moment and then stops. if i try the hot water when the central heating is on then i get hot water. i will also get hot water for a short period after the central heating is switched off. |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4249 Location: Bath
|
Posted: Tue May 27, 2003 7:24 pm Post subject: |
|
|
Sounds like the divertor valve, send me an email.
thescruff 8) |
|
| Back to top |
|
 |
|