keep existing house wiring while removing entire roof system

 
Post new topic   Reply to topic    Ask the Question Forum Index -> Ask the Builder
Author Message
jmagana



Joined: 22 Nov 2004
Posts: 1
Location: California

PostPosted: Mon Nov 22, 2004 7:42 pm    Post subject: keep existing house wiring while removing entire roof system Reply with quote

Please read the following email response to my question. What suggestions do you have. I don't want to imagine tearing into existing walls.


What you have suggested is the only real way of doing it, but I would renew
the wiring as a matter of course while I had the chance.
I take it you are in the states and I would suggest you forward this message
to 'B' who is state side and knows all the local codes.

Regards

Vince
----- Original Message -----
From: <jmrmagana@comcast.net>
To: <enquiries@vkelectrical.com>
Sent: Monday, November 22, 2004 7:02 AM
Subject: electrical wiring of addition


>
> Hello vince knight,
>
> The following is an email sent to you by jmagana via your account on Ask
the Question. If this message is spam, contains abusive or other comments
you find offensive please contact the webmaster of the board at the
following address:
>
> webmaster@askthequestion.co.uk
>
> Include this full email (particularly the headers). Please note that the
reply address to this email has been set to that of jmagana.
>
> Message sent to you follows
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~
>
> My uncle is planning to remodel his house. He wants to add approximately
1000 s.f. of additional conditioned space. He currently has a 4:12 pitch
roof and does not like it. He will be taking the entire roof system off to
set the pitch to 6:12. All the electrical wiring in the attic placed over
the ceiling joists will cause a problem once he begins to remove the roof
system. Because the new roof will be pre-engineered trusses, the ceiling
joists will have to be removed.
>
> What do you recommend to do being that he would like to keep the existing
electric panel and not change the current circuit wiring he currently has?
>
> I was thinking it may be possible to have an electrician disconnect all
the circuits from the breaker panel, remove the existing roof system, place
the new trusses, and then have the electrician fish the existing wiring back
to the panel exactly how it was before. For the new addition, new circuits
would be placed.
>
> My suggestion is likely not practical so I am looking for your advice. In
terms of cost, if all this is being completed, would you recommend that the
main panel be replaced since it is likely a 1970's panel?
>
>
> Thanks in advance for your recommendations.
>
>
Back to top
vince knight
Moderator


Joined: 04 Mar 2004
Posts: 1334
Location: Essex/East London

PostPosted: Tue Nov 23, 2004 8:30 pm    Post subject: Reply with quote

B, can you take this one mate?

Vince