| Author |
Message |
Jonty
Joined: 26 May 2008 Posts: 5 Location: Lincolnshire, UK
|
Posted: Tue Jun 03, 2008 2:43 pm Post subject: Sysytem Cleanout |
|
|
I have a Rayburn cooker/boiler driving 11 radiators and domestic hot water. The heating side is hopelessly innefficient with only the top 6 inches of each radiator getting hot. The system is clearly sludged up and I would like to clean it out including the pipework and boiler.
Any advice on the best way to do this and any potential pitfalls would be very gratefully received. Oil prices being what they are I feel like I'm just throwing money away!
Cheers. |
|
| Back to top |
|
 |
th4rn
Joined: 04 Jun 2008 Posts: 3 Location: uk
|
Posted: Wed Jun 04, 2008 5:53 pm Post subject: |
|
|
| either get a professional to powerflush your radiators or turn off the mains water and take the rads of the wall one by one and clear them out with clean water |
|
| Back to top |
|
 |
Jonty
Joined: 26 May 2008 Posts: 5 Location: Lincolnshire, UK
|
Posted: Thu Jun 05, 2008 8:18 pm Post subject: |
|
|
I am going to take the rads off anyway-I've done this before one by one. I was more concerned with flushing out the pipework and the boiler after the rads are removed.
Any thoughts anyone? |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4605 Location: Bath
|
Posted: Thu Jun 05, 2008 9:43 pm Post subject: |
|
|
| please remember the cooker needs 24-48 hours to cool down before you drain the water. |
|
| Back to top |
|
 |
AlanE Moderator
Joined: 29 Jun 2003 Posts: 1318 Location: Colchester Essex
|
Posted: Fri Jun 06, 2008 9:34 am Post subject: |
|
|
Hire a powerflushing machine!
Dose the system with cleaner and run for 2 to 3 weeks then hire a flushing machine to flush the system out. Take around a day but everything, rads and pipes will be a lot cleaner than simply taking off wall and flushing.
Alternanatly dose system as above, make up adapters to convert pump couplings to accept hose and flush with mains pressure through system one rad at a time. Not as effective as machine.
Get a rubber hammer to hit each rad as you are flushing it whatever way you do it. |
|
| Back to top |
|
 |
Jonty
Joined: 26 May 2008 Posts: 5 Location: Lincolnshire, UK
|
Posted: Fri Jun 06, 2008 2:15 pm Post subject: |
|
|
Thanks for those thoughts. I was warned against using a powerflusher given that half the system is over 25 years old and the other half is in a big extension we built 10 years ago. I was told that powerflushing may reveal weaknesses in some of the older pipework and joints. My main concern is making sure that the Rayburn boiler gets cleaned out as it's retaining too much heat. If I don't use a powerflusher how can I achieve this? I don't want to undo the heavy duty pipework to the boiler as this will seriously reveal my own shortcomings at plumbing!
Meant to add!
If I use a powerflusher can I do this without removing the radiators? |
|
| Back to top |
|
 |
Yellowman
Joined: 03 Jan 2008 Posts: 77 Location: Sussex
|
Posted: Fri Jun 06, 2008 3:51 pm Post subject: |
|
|
You can get a pump head adaptor for the flushing machine. basically you remove the head of the pump and this screws in its place.
Withy the machine you can actually circulate and clean the boiler without acually having to touch the connections.
I have powerflushed a few older systems and never had problems to be honest. |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4605 Location: Bath
|
Posted: Fri Jun 06, 2008 9:11 pm Post subject: |
|
|
Before we go too far it would be handy to know a little bit more about the cooker model etc.
Most Rayburn type cookers have a limited output for heating and hot water, I suggest you are way over that limit without more information. |
|
| Back to top |
|
 |
AlanE Moderator
Joined: 29 Jun 2003 Posts: 1318 Location: Colchester Essex
|
Posted: Sat Jun 07, 2008 5:59 am Post subject: |
|
|
That is a good point Scruff. Just reread the original post and there are 11 rads.
Try turning off say half of them and what happens? If they now get hot vertually all over then it's not sludge.
Have they ever all worked properly? What are the approx sizes, & types, of radiators. |
|
| Back to top |
|
 |
Jonty
Joined: 26 May 2008 Posts: 5 Location: Lincolnshire, UK
|
Posted: Sun Jun 08, 2008 6:35 pm Post subject: |
|
|
Thanks all for the input. Rayburn is a 760k model designed to feed minimum 12 ordinary sized domestic rads and the hot water. System worked fine for about four years after installation then has gone steadily downhill. The pump is over-capacity and was renewed four years ago. I have, over the last five years, sporadically taken radiators off and cleaned them out, turning upside-down and banging with a soft mallet whilst flushing with a high-pressure hosepipe, putting back on and bleeding copiously.They then work fine for a while until the gunge circulates round the system again. We have a mixture of older (steel) radiators about 26/27 years old and some more lightweight radiators about 10/12 years old. Would I be better to replace all the older part of the sysytem.
Still would like to know how to flush out the pipework and boiler!
Thanks. |
|
| Back to top |
|
 |
AlanE Moderator
Joined: 29 Jun 2003 Posts: 1318 Location: Colchester Essex
|
Posted: Sun Jun 08, 2008 7:41 pm Post subject: |
|
|
| Quote: | Still would like to know how to flush out the pipework and boiler!
|
Look at my post about 6 posts up and I thought I had fully described how. Sorry but you really only have two choices hire a powerflushing machine, which is the prefered method.
The other is to remove pump, you would need to do this with machine, and make up a pair of adapters so that you can connect hosepipes to each pump connection and blast mains pressure around system 1 rad at a time. Reverse connections and do same with flow the other way.
If you used the second method and then used the machine afterwards you would be surprised just how much more muck it gets out.
However you do it Inhibiter in system afterwards and fit a magnaclean to the system.
Finally if you opt for the rads off the wall method you will in reality just dilute the muck since there will be loads left behind in the pipes. |
|
| Back to top |
|
 |
Jonty
Joined: 26 May 2008 Posts: 5 Location: Lincolnshire, UK
|
Posted: Wed Jun 11, 2008 2:40 pm Post subject: |
|
|
Many thanks for all those comments-very gratefully received.
I've decided to go down the powerflushing route. Nothing ventured etc! |
|
| Back to top |
|
 |
Yellowman
Joined: 03 Jan 2008 Posts: 77 Location: Sussex
|
Posted: Fri Jun 13, 2008 3:12 pm Post subject: |
|
|
| Good decision. |
|
| Back to top |
|
 |
|