| Author |
Message |
cooky5
Joined: 01 Apr 2008 Posts: 3 Location: scunthorpe
|
Posted: Tue Apr 01, 2008 6:52 am Post subject: No Hot Water! |
|
|
| The pressure dial on my combi boiler shows just above 0, how can the pressure be increased? |
|
| Back to top |
|
 |
poolcorgi Moderator
Joined: 19 Oct 2004 Posts: 395 Location: ashland city TN USA
|
Posted: Tue Apr 01, 2008 7:55 am Post subject: |
|
|
| make / model of boiler ?? |
|
| Back to top |
|
 |
cooky5
Joined: 01 Apr 2008 Posts: 3 Location: scunthorpe
|
Posted: Tue Apr 01, 2008 12:36 pm Post subject: |
|
|
Worcester 24cdi
Also the hot water is ok when the heating is on but still runs very slow. |
|
| Back to top |
|
 |
poolcorgi Moderator
Joined: 19 Oct 2004 Posts: 395 Location: ashland city TN USA
|
Posted: Tue Apr 01, 2008 12:44 pm Post subject: |
|
|
remove the bottom panel from the boiler insert the plastic filling key and open the grey knob watch the pressure gauge 1.2 cold
then reverse the procedure
if you need the book e mail me  |
|
| Back to top |
|
 |
cooky5
Joined: 01 Apr 2008 Posts: 3 Location: scunthorpe
|
Posted: Tue Apr 01, 2008 12:54 pm Post subject: |
|
|
| Thanks for your advice, i bought my house at the end of last year, the previous owner did not leave the book or filling key, can this work be done witout the filling key? again thanks for your help |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4659 Location: Bath
|
Posted: Tue Apr 01, 2008 1:04 pm Post subject: |
|
|
Yes you could attach an hose pipe to a draincock.
If the pressure has suddenly dropped, you will have to suspect the expansion vessel has gone or lost its charge.
PTS, Plumbase, Plumstop etc should have the key. |
|