Ask the Question Forum Index Ask the Question
FREE question and answer forums in a variety of subjects
 
 FAQFAQ   SearchSearch   UsergroupsUsergroups   RegisterRegister 
 ProfileProfile   Log in to check your private messagesLog in to check your private messages   Log inLog in 

installing an indirect hot water cylinder - leaking feeds
Goto page Previous  1, 2
 
Post new topic   Reply to topic    Ask the Question Forum Index -> Ask the Plumber
Author Message
thescruff
Moderator


Joined: 03 May 2003
Posts: 4386
Location: Bath

PostPosted: Tue Mar 25, 2008 7:19 pm    Post subject: Reply with quote

cbushnell wrote:
Yeah I expect you're right. God save us from well meaning amateurs.
We're very grateful from your help.

Best regards,

Clive


Louise said to say thank you for the donation Laughing this is her first time and looking to do really well. So again
Thank You

john
Back to top
straker1966



Joined: 06 Jan 2008
Posts: 164
Location: cambridge

PostPosted: Tue Mar 25, 2008 8:03 pm    Post subject: Reply with quote

cylinder thermostats should ALWAYS be 1/3 of the way up from the bottom of the cylinder...
i know this cos the crusty old bushy sideburns miserable git of a plumber i did my time with told me so..... Crying or Very sad
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4386
Location: Bath

PostPosted: Tue Mar 25, 2008 8:05 pm    Post subject: Reply with quote

straker1966 wrote:
cylinder thermostats should ALWAYS be 1/3 of the way up from the bottom of the cylinder...
i know this cos the crusty old bushy sideburns miserable git of a plumber i did my time with told me so..... Crying or Very sad


But why, that is the question Rolling Eyes

Where would you find an immersion heater stat

And what height do you fit an room stat Laughing
Back to top
Yellowman



Joined: 03 Jan 2008
Posts: 66
Location: Sussex

PostPosted: Tue Mar 25, 2008 11:24 pm    Post subject: Reply with quote

I was alo taught to put the stat a third of the way up.

Reason being if its high up only the top half of the cylinder will contain a decent volume of hot water. the lower down the colder the water.

Where as at the bottom your garuntee'd all the water above is at the set temp on the stat.

Unvented cylinders come with the stat roughly a third up; this must be for a reason.

Immersion heaters are a boost or a back up. Its quicker and cheaper to heat up just the top section of the tank (enough water for shower or bath) Economy 7 have the off peak imersion heater at the bottom but its billed at a lower rate and time does not matter as much so it can heat up a nice full cylinder of water. The booster immersion is higher up, again just to heat up top half of cylinder.


Id imagine room stats were set at the height they are due to the way that heat convects around a room let alone to save dear old granny smith getting on her hands and knees to turn her heating on.

Just my 2p and what i was taught
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4386
Location: Bath

PostPosted: Wed Mar 26, 2008 12:13 am    Post subject: Reply with quote

Thats worth a tenner just to read it Yellowman Laughing

If the stat is set at 65c in the bottom 1/3rd, then the water above it will rise to 75c, Logical don't you think being as how the heat rises.

By the same token, and this is the good bit Laughing why isn't the room stat 1/3rd up the wall, when you're sat in the chair all the good heat is above your head. Rolling Eyes
Back to top
straker1966



Joined: 06 Jan 2008
Posts: 164
Location: cambridge

PostPosted: Wed Mar 26, 2008 7:07 pm    Post subject: Reply with quote

2 against one scruff- you lose! Mr. Green

1/3 of the way up, its written in the bible...

"THOU SHALT SLICE THAT HOLY FOAM NO LESS THAN ONE THIRD UP...AMEN"

the reason roomstats are fitted so high is to stop the cat upping the temp when your out Idea
Back to top
poolcorgi
Moderator


Joined: 19 Oct 2004
Posts: 385
Location: ashland city TN USA

PostPosted: Wed Mar 26, 2008 7:21 pm    Post subject: Reply with quote

Quote:
the reason roomstats are fitted so high is to stop the cat upping the temp when your out Idea


wouldnt stop ours the gits would form a pyramid Laughing Laughing Laughing
Back to top
A.C.Judd



Joined: 09 Jan 2008
Posts: 6
Location: kent

PostPosted: Wed Mar 26, 2008 9:24 pm    Post subject: Reply with quote

tell me if im wrong scruff but shouldent that cylinder be on blocks of wood to stop it corroding
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4386
Location: Bath

PostPosted: Thu Mar 27, 2008 1:14 am    Post subject: Reply with quote

Yes it should be on battens for air circulation not corrosion
Back to top
Yellowman



Joined: 03 Jan 2008
Posts: 66
Location: Sussex

PostPosted: Thu Mar 27, 2008 6:56 pm    Post subject: Reply with quote

If its not on battons condensation can form underneath the cylinder.

Scruff - Why you being sarcastic for? I was only saying what I have been taught from college. I wasnt saying you were wrong. I repsect your knowledge and I like to read your input on most posts to futher my knowledge.
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4386
Location: Bath

PostPosted: Thu Mar 27, 2008 7:26 pm    Post subject: Reply with quote

Yellowman wrote:
If its not on battons condensation can form underneath the cylinder.

Scruff - Why you being sarcastic for? I was only saying what I have been taught from college. I wasnt saying you were wrong. I repsect your knowledge and I like to read your input on most posts to futher my knowledge.


I wasn't being sarcastic, It was light hearted banter Laughing

The tenner ref was for the race for life charity appeal Laughing
Back to top
Yellowman



Joined: 03 Jan 2008
Posts: 66
Location: Sussex

PostPosted: Thu Mar 27, 2008 7:39 pm    Post subject: Reply with quote

Oh i see!
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Ask the Question Forum Index -> Ask the Plumber All times are GMT
Goto page Previous  1, 2
Page 2 of 2

 




Powered by phpBB © 2001, 2005 phpBB Group