| Author |
Message |
bobbych
Joined: 17 Mar 2006 Posts: 32 Location: NORTH EAST UK
|
Posted: Sun Mar 16, 2008 6:39 pm Post subject: New Soil Connection |
|
|
Hi
I need to fit a branched connector into an existing stack on the ground floor for a new WC. Due to restrictions I am unable to cut and lift the stack to get the new fitting in. Are there and fittings to overcome this or any tricks?
Cheers |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4400 Location: Bath
|
Posted: Sun Mar 16, 2008 6:49 pm Post subject: |
|
|
| Yes buy an slip socket and slide it right over the pipe, fit the branch and slide the socket down to the center of the two ends |
|
| Back to top |
|
 |
bobbych
Joined: 17 Mar 2006 Posts: 32 Location: NORTH EAST UK
|
Posted: Sun Mar 16, 2008 7:01 pm Post subject: |
|
|
| Nice one. Cheers |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4400 Location: Bath
|
Posted: Sun Mar 16, 2008 11:55 pm Post subject: |
|
|
Concentrate on getting the branch in the right place, the socket can be say 3-400mm above the branch.
You will find that O ring fittings will be easier to work with as well, and use plenty of silicon grease |
|
| Back to top |
|
 |
|