Ask the Question Forum Index Ask the Question
FREE question and answer forums in a variety of subjects
 
 FAQFAQ   SearchSearch   UsergroupsUsergroups   RegisterRegister 
 ProfileProfile   Log in to check your private messagesLog in to check your private messages   Log inLog in 

Hot water problem

 
Post new topic   Reply to topic    Ask the Question Forum Index -> Ask the Plumber
Author Message
Hartnack



Joined: 18 Feb 2008
Posts: 2
Location: Sunderland

PostPosted: Mon Feb 18, 2008 12:13 am    Post subject: Hot water problem Reply with quote

I have a Glow Worm Condenser Combi boiler, which is less than two years old. For some reason, hot water is not consistantly being delivered to the upstairs of my house. Sometimes water is warm but not hot and sometimes it alternates from being warm to freezing cold. Can you please advise what the problem might be? Is it a plumbing problem or a boiler problem?
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4755
Location: Bath

PostPosted: Mon Feb 18, 2008 12:18 am    Post subject: Reply with quote

Could be either, what is the model, and what outlets are affected
Back to top
Hartnack



Joined: 18 Feb 2008
Posts: 2
Location: Sunderland

PostPosted: Mon Feb 18, 2008 12:28 am    Post subject: No hot water Reply with quote

Boiler is a Glow Worm 38CXI.
The outlets affected are upstairs baths, showers in particular. Basin taps normally deliver water which is consistantly hotter than the other outlets but not brilliantly hot.
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4755
Location: Bath

PostPosted: Mon Feb 18, 2008 9:59 am    Post subject: Reply with quote

Are the mixer taps and especially the shower mains fed
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4755
Location: Bath

PostPosted: Mon Feb 18, 2008 11:26 pm    Post subject: Reply with quote

In an Pm Hartnack said.

Quote:
Mixer taps - hot direct from boiler and cold supply mains fed.

Are you supposed to use special taps for combi boilers?


I would suspect the cold is backing up the hot pipe, first choice would be the shower.

Turn the cold mains feeding the boiler off, then open an hot tap, preferably one thats not a mixer, then open the hot and cod on each appliance one at a time until you get a feed back out of the hot tap.

Depending on the make/model the shower valve may not have any water.

Another way you may have to check, is to isolate each cold outlet local to the tap, then run the hot until it is hot, then turn the cold valve on and see if the hot pipe cools.
Back to top
Display posts from previous:   
Post new topic   Reply to topic    Ask the Question Forum Index -> Ask the Plumber All times are GMT - 1 Hours
Page 1 of 1

 




Powered by phpBB © 2001, 2005 phpBB Group
Adverse Credit Remortgage | Guitar Lessons | Loans | Balance Transfer Credit Cards | Internet advertising