Posted: Mon Feb 18, 2008 12:13 am Post subject: Hot water problem |
|
|
| I have a Glow Worm Condenser Combi boiler, which is less than two years old. For some reason, hot water is not consistantly being delivered to the upstairs of my house. Sometimes water is warm but not hot and sometimes it alternates from being warm to freezing cold. Can you please advise what the problem might be? Is it a plumbing problem or a boiler problem? |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4755 Location: Bath
|
Posted: Mon Feb 18, 2008 12:18 am Post subject: |
|
|
| Could be either, what is the model, and what outlets are affected |
|
| Back to top |
|
 |
Hartnack
Joined: 18 Feb 2008 Posts: 2 Location: Sunderland
|
Posted: Mon Feb 18, 2008 12:28 am Post subject: No hot water |
|
|
Boiler is a Glow Worm 38CXI.
The outlets affected are upstairs baths, showers in particular. Basin taps normally deliver water which is consistantly hotter than the other outlets but not brilliantly hot. |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4755 Location: Bath
|
Posted: Mon Feb 18, 2008 9:59 am Post subject: |
|
|
| Are the mixer taps and especially the shower mains fed |
|
| Back to top |
|
 |
thescruff Moderator
Joined: 03 May 2003 Posts: 4755 Location: Bath
|
Posted: Mon Feb 18, 2008 11:26 pm Post subject: |
|
|
In an Pm Hartnack said.
| Quote: | Mixer taps - hot direct from boiler and cold supply mains fed.
Are you supposed to use special taps for combi boilers? |
I would suspect the cold is backing up the hot pipe, first choice would be the shower.
Turn the cold mains feeding the boiler off, then open an hot tap, preferably one thats not a mixer, then open the hot and cod on each appliance one at a time until you get a feed back out of the hot tap.
Depending on the make/model the shower valve may not have any water.
Another way you may have to check, is to isolate each cold outlet local to the tap, then run the hot until it is hot, then turn the cold valve on and see if the hot pipe cools. |
|
| Back to top |
|
 |
|