PostPosted: Mon Oct 09, 2006 7:24 am    Post subject: Vokera Linea 24 hot water Reply with quote

I have a double whammy here!
My ex-wife and her neighbour both have a vokera linea 24 combi-boiler.
Both are experiencing very similar hot water problems.
The water runs warm then cool on all taps in the system.
Have had gas and water pressure tested and all is ok.
Could be coincidence that both are doing the same thing.
My ex definately has a slight leak in the heating side as the filling loop occasionally needs topped up. The neighbour recently had a radiator temporarily removed whilst redecorating. Could the problem be related to any of this?
A further symptom on my ex's system (but not the neighbour) is that when trying to run hot water the pilot light ignites and extinguishes every 4 or 5 seconds yet stays on when running the heating. There is no pilot light problem with the neighbour's boiler.
Any help appreciated, thanks.
Back to top
AlanE
Moderator


Joined: 29 Jun 2003
Posts: 1418
Location: Colchester Essex

PostPosted: Mon Oct 09, 2006 8:17 am    Post subject: Reply with quote

Blocked plate heat exchanger on both.
Back to top
Lisdar



Joined: 03 Oct 2006
Posts: 30
Location: Wales

PostPosted: Wed Jan 17, 2007 8:46 pm    Post subject: Reply with quote

AlanE wrote:
Blocked plate heat exchanger on both.



Know this thread is a bit old but have two Lineas 24 and they have the same fault
gas lights then extinguishes every 4/5 seconds on Water and Heating
also what is a plate heat exchange

Razz
Back to top
thescruff
Moderator


Joined: 03 May 2003
Posts: 4755
Location: Bath

PostPosted: Wed Jan 17, 2007 9:59 pm    Post subject: Reply with quote

A recycled bean can that heats the hot water, should find it in the Mi manual
Back to top
Lisdar



Joined: 03 Oct 2006
Posts: 30
Location: Wales

PostPosted: Sun Nov 25, 2007 1:06 pm    Post subject: Linea 24 Reply with quote

fixed this one after,
gas valve control board on side of valve all ok now